Air Leakage Testing Services
Commercial - TSL 2 - Residential - TSL 1
Get a Free Quote
Design meeting with the Project Team on site
A review of existing drawings from an air tightness perspective
Summarising bullet-point email within 10 working days
Targeted at establishing an airtight barrier at an early stage
Targeted at minimising the risk of a final air test fail
Design review of architectural drawings
A review of up to 30 section detail drawings
Report and annotated drawings within 7 working days of booking
Targeted at minimising the risk of a final air test fail
If working in a portal, relevant drawings to be selected by the client and placed in a folder. All drawings to be in pdf format.
Construction consultancy site inspection with report
Monitoring of the airtight barriers construction and identifying leakage paths as they rise during construction
Site Pro Report
Targeted at minimising the risk of a final air test fail
Pre-test consultancy visit with photographic report
With or without pressurisation
Identifies possible leakage paths before the final test so allowing time for site to carry out remedial works before the final test
Site Pro Report
Targeted at minimising the risk of a final air leakage test fail
Final Air Leakage Testing of single buildings
Envelope area calculation included
To perform an initial air permeability test
In the event of a fail, to perform localised smoke testing to identify leakage paths as part of the service
After remedial work by site, to perform an additional air permeability test
Repeat the process as many times as required or possible within the time allocated on site
Sitepro fail report, if required or requested, within 7 working days
Declaration of result / certificates within 7 working days
Final Air Leakage Testing of multiple units on a visit
Envelope area calculation included
To perform an initial air permeability test
In the event of a failure, to perform localised smoke testing to identify leakage paths as part of the service
After remedial work by site, to perform an additional Whole Building Air Permeability Test before moving on to the next unit
Repeat the service on the next unit
Sitepro fail report, if required or requested, within 7 working days
Declaration of result / certificates within 7 working days
Smoke shaft testing
Perform air permeability test
In the event of a fail, localized smoke testing to identify leakage paths included
After remedial work by site, to perform an additional Air Permeability Test
Sitepro fail report, if required or requested, within 7 working days
Declaration of result / certificates within 7 working days
Passivhaus testing
Visit One:
Initial air test using pressurisation & depressurisation
Temporary sealing of designed ventilation permitted
Localized smoke test to advise on leakage paths
Visit Two:
Repeat initial air test after first fix
Services as per above
Visit Three:
Final air test after completion of build
Pressure test only, no temporary sealing permitted
Leakage path report if required